TM 9-2320-365-20-1
2-745
CONTINUITY TEST
(1) Remove instrument panel assembly for access
(para 7-15).
(2) Disconnect connector PX15 from main light
switch.
(3) Connect positive (+) probe of multimeter to
connector PX15-K.
(4) Connect negative (-) probe of multimeter to
PDP, terminal 87, where relay K6 was removed,
and note reading on multimeter.
(5) If continuity is not present, repair wire 1404
(para 2-40) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(6) If continuity is present, replace relay K6
(para 7-9).
(7) Install relay K6 in PDP.
(8) Install PDP cover (para 16-2).
(9) Connect connector PX15 to main light switch.
(10) Install instrument panel assembly (para 7-15).