TM 9-2320-365-20-1
2-940
1.
START
YES
NO
Circuit breaker OK.
PTO OK.
Is 24 vdc present on
connector P902 terminal 6?
If 24 vdc is not present,
wire 1904 is faulty.
KNOWN INFO
POSSIBLE PROBLEMS
Faulty auxiliary panel
cable assembly.
Faulty winch power
switch.
Faulty WINCH IN/OUT
switch.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R #89
REASON FOR QUESTION
e85. 11K SELF-RECOVERY WINCH DOES NOT REEL IN OR PAY OUT
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
Personnel Required
(2)
Materials/Parts
Wire, Elect, 50 ft (Item 77, Appendix D)
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
Repair wire 1904 (para 2-40)
or replace auxiliary panel
cable assembly (all models
except M1079 w/o winch)
(para 7-49).