TM 9-2320-365-20-1
2-1051
CONTINUITY TEST
(1) Raise cab (TM 9-2320-365-10).
(2) Disconnect connector P42 from ether sensor
connector.
(3) Connect jumper wire to connector P42-2.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter to
connector P31-2.
(6) Connect negative (-) probe of multimeter to
jumper wire and note reading on multimeter.
(7) If continuity is not present, repair wire 1402
(para 2-40) or replace engine control cable
assembly (para 7-72).