YES
e108. M1079 110 VDC OUTLET J232 DOES NOT OPERATE IN NORMAL MODE
TM 9-2320-365-20-2
2-1176 Change 1
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
(2)
References
TM 9-4910-571-12&P
START
1.
KNOWN INFO
TEST OPTIONS
Operational Test
REASON FOR QUESTION
POSSIBLE PROBLEMS
Fluorescent lights OK.
Faulty 110 VAC receptacle
J232.
Faulty wire 1499B.
Faulty wire 3085K.
Faulty wire 3085AA.
Faulty circuit breaker CB5.
Faulty wire 701A.
Faulty wire 702A.
Faulty relay K35.
Does 110 VAC outlet J233
operate?
This question eliminates
possible problems and
determines where
troubleshooting continues.
NO
Go to step 5 of this fault.