Change 1 2-1203
TM 9-2320-365-20-2
CONTINUITY TEST
(1) Disconnect AC power (TM 9-2320-365-10).
(2) Remove six screws and cover from 110/208
VAC POWER DISTRIBUTION PANEL.
(3) Remove circuit breaker CB7 from 110/208
VAC POWER DISTRIBUTION PANEL.
(4) Position circuit breaker CB7 to ON
(TM 9-2320-365-10).
(5) Set multimeter to ohms.
(6) Connect positive (+) probe of multimeter to
output terminal of circuit breaker CB7.
(7) Connect negative (-) probe of multimeter to
input terminal of circuit breaker CB7 and
note reading on multimeter.
(8) If continuity is not present, replace circuit
breaker CB7 (para 16-64).
(9) Install circuit breaker CB7 on 110/208 VAC
POWER DISTRIBUTION PANEL.