TM 9-2320-365-20-2
2-1264
1.
START
YES
NO
KNOWN INFO
TEST OPTIONS
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
AC power disconnected (TM 9-2320-365-10).
Personnel Required
(2)
Continuity Test or
STE/ICE-R #91
REASON FOR QUESTION
e115. M1079 AIR CONDITIONER DOES NOT OPERATE
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
TM 5-4120-384-14
Fluorescent lights OK.
110 vac outlets OK.
POSSIBLE PROBLEMS
Is continuity present
across circuit breaker
CB2?
If continuity is not present,
circuit breaker CB2 is
faulty.
Replace circuit breaker
CB2 (para 16-64).
Faulty circuit breaker CB2.
Faulty wire 1500.
Faulty wire 1501.
Faulty wire 1505.
Faulty wire 1499.
Faulty M1079 A/C power
cable.
Faulty air conditioner.