TM 9-2320-365-20-2
2-1281
CONTINUITY TEST
(1) Loosen screw in terminal board TB3.
(2) Remove wire 3085A from terminal board TB3.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
wire 3085A.
(5) Connect negative (-) probe of multimeter to
HEATER connector J244 socket D and note
reading on multimeter.
(6) If continuity is not present, repair or replace wire
3085A (para 2-40).
(7) Install wire 3085A on terminal board TB3.
(8) Tighten screw in terminal board TB3.
(9) Install wire 1499A on terminal board TB4.
(10) Tighten screw in terminal board TB4.
(11) Install cover on 110/208 VAC POWER
DISTRIBUTION PANEL with six screws.