TM 9-2320-365-20-2
2-1306
e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT)
KNOWN INFO
YES
NO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
Blackout lights OK.
Emergency lights OK.
Fuse OK.
POSSIBLE PROBLEMS
6.
If continuity is not present,
wire 1507 is faulty.
Faulty M1079 12/24 vdc
power cable.
Faulty circuit breaker
CB11.
Faulty wire 49.
Faulty positive 24 vdc
binding post.
Faulty wire 3085L.
Faulty negative 24 vdc
binding post.
Is continuity present
from left end of fuse
holder to terminal lug
TL100?
Repair wire 1507 (para 2-40) or
replace M1079 12/24 vdc power
cable (para 7-51).