TM 9-2320-365-20-2
2-1319
CONTINUITY TEST
(1) Remove six screws and cover from 110/208
VAC POWER DISTRIBUTION PANEL.
(2) Loosen screw in terminal board TB3.
(3) Remove wire 3085L from terminal board TB3.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter to
J237 24 vdc ground (G) binding post.
(6) Connect negative (-) probe of multimeter to
terminal board TB3 wire 3085L and note
reading on multimeter.
(7) If continuity is not present, repair or replace
wire 3085L (para 2-40).
(8) Position wire 3085L in terminal board TB3.
(9) Tighten screw in terminal board TB3.
(10) Install cover on 110/208 VAC POWER
DISTRIBUTION PANEL with six screws.