TM 9-2320-365-20-2
2-1322
KNOWN INFO
YES
NO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
14.
If continuity is not present,
J237 negative binding post
is faulty. If continuity is
present, wire 3086 is
faulty.
Blackout lights OK.
Emergency lights OK.
Fuse OK.
M1079 12/24 vdc
power cable OK.
Wire 1507 OK.
Circuit breaker CB11 OK.
Wire 49 OK.
Positive binding post OK.
Wire 3085L OK.
Ground binding post OK.
POSSIBLE PROBLEMS
Faulty negative 24 vdc
binding post.
Faulty wire 3086.
Is continuity present
across J237 24 vdc
negative (-) binding post?
Replace negative binding
post (para 16-52).
Repair or replace
wire 3086 (para 2-40).
e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT)