TM 9-2320-365-20-2
2-1323
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
inside of J237 negative (-) binding post.
(3) Connect negative (-) probe of multimeter to
front side of J237 negative (-) binding post
and note reading on multimeter.
(4) If continuity is not present, replace J237 24 vdc
negative binding post (para 16-52).
(5) If continuity is present, repair or replace
wire 3086 (para 2-40).
(6) Install cover on J237 24 vdc outlet box with
two screws.
(7) Connect M1079 12/24 vdc power cable to van
body (TM 9-2320-365-10).