TM 9-2320-365-20-2
2-1338
1.
START
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
12/24 vdc circuits OK.
POSSIBLE PROBLEMS
Faulty circuit breaker CB1.
Faulty wire 1499N.
Faulty wire 3085N.
Faulty wire 3085P.
Faulty wire 3085Q.
Faulty wire 3085R.
Faulty wire 3085Y.
Faulty wire 500.
Faulty wire 501.
Faulty wire 502.
Is continuity present
across circuit breaker
CB1 left terminal?
If continuity is not present,
circuit breaker CB1 is
faulty.
e119. M1079 110 VAC POWER DOES NOT OPERATE
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
AC power disconnected (TM 9-2320-365-10).
Materials/Parts
Wire, Electrical, 50 ft (Item 77, Appendix C)
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
Replace circuit breaker CB1
(para 16-65).