TM 9-2320-365-20-2
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
6.
Fluorescent lights OK.
Circuit breaker CB8 OK.
Fan switch S35 OK.
Fan OK.
Wire 415 OK.
Wire 415A OK.
POSSIBLE PROBLEMS
Faulty wire 1499H.
Faulty wire 3085X.
Faulty wire 3085F.
Faulty wire 3085Z.
Is continuity present on
wire 1499H from one end
to the other?
If continuity is not present,
wire 1499H is faulty.
Repair or replace wire
1499H (para 2-40).
YES
NO
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
POSSIBLE PROBLEMS
7.
Fluorescent lights OK.
Circuit breaker CB8 OK.
Fan switch S35 OK.
Fan OK.
Wire 415 OK.
Wire 415A OK.
Faulty wire 1499H.
Faulty wire 3085X.
Faulty wire 3085F.
Faulty wire 3085Z.
Is continuity present on
wire 1499H from power
distribution panel to fan
switch S35 outlet box?
If continuity is not present,
wire 1499H is faulty.
Repair or replace wire
1499H (para 2-40).
e99. M1079 FAN DOES NOT OPERATE (CONT)
2-1094