CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to connector J119j.
(3) Connect negative (-) probe of multimeter to
connector P114-12 and note reading on
multimeter.
(4) Connect negative (-) probe of multimeter to
all other sockets in connector P114, one at
a time, and note reading on multimeter.
(5) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6) If continuity is not present in step 3, or
continuity is present in step 4 or 5, replace
WTEC III cab transmission harness (para
7-87).
Change 1 2-1529
TM 9-2320-365-20-2