TM 9-2320-365-20-2
2-1141
CONTINUITY TEST
(1) Open door on 110/208 VAC POWER
DISTRIBUTION PANEL (TM 9-2320-365-10).
(2) Position circuit breaker CB1 to OFF
(TM 9-2320-365-10).
(3) Remove two screws and cover from
INTERIOR LIGHTS switch outlet box.
(4) Remove ballast cover from lighting fixture
DS82.
(5) Set multimeter to ohms.
(6) Connect positive (+) probe of multimeter to
bottom left pole of switch S32.
(7) Connect negative (-) probe of multimeter to
wire 706B in lighting fixture DS82 and note
reading on multimeter.
(8) If continuity is not present, repair or replace
wire 706B from lighting fixture DS83 to
DS82 (para 2-40).
(9) Install cover on INTERIOR LIGHTS switch
outlet box with two screws.
(10) Close door on 110/208 VAC POWER
DISTRIBUTION PANEL (TM 9-2320-365-10).