TM 9-2320-365-20-3
7-2. 100 AMP ALTERNATOR REPLACEMENT (CONT)
(6) Remove screw (13), washer (14), and clamp (15) from
alternator (6).
(7) Lift dust boot (16) on terminal lug TL2 (17).
(8) Remove self-locking nut (18), washer (19), terminal lugs
TL2 (17) and TL6 (21), and two washers (22) from
alternator (6).
(9) Position two washers (22), washer (19), and self-locking
nut (18) on alternator (6).
(10) Lift dust boot (23) on terminal lug TL35 (24).
(11) Remove self-locking nut (25), washer (26), and terminal
lug TL35 (24) from voltage regulator (27).
(12) Position washer (26) and self-locking nut (25) on voltage
regulator (27).
(13) Lift dust boot (28) on terminal lug TL110 (29).
(14) Remove self-locking nut (30), washer (31), and terminal
lug TL110 (29) from voltage regulator (27).
(15) Position washer (31) and self-locking nut (30) on voltage
regulator (27).
7-4
Change 1