TM 9-2320-365-20-3
7-77. POWER TAKE-OFF (PTO) CABLE ASSEMBLY REPLACEMENT (CONT)
b. Installation.
NOTE
Install plastic cable ties as required.
(1) Position PTO cable assembly (1) in cab (2).
(2) Connect connector J210 (3) to connector P210 (4).
(3) Position PTO cable assembly (1) in clamp (5).
(4) Position clamp (5) and clamp (6) on frame rail (7) with
screw (8) and self-locking nut (9).
(5) Tighten self-locking nut (9) to 84-108 lb-in. (10-12 N·m).
(6) Position PTO cable assembly (1) in clamp (10).
(7) Position clamp (10) on frame rail (7) with screw (11) and
self-locking nut (12).
(8) Tighten self-locking nut (12) to 84-108 lb-in. (10-12 N·m).
7-324