TM 9-2320-365-20-4
16-50. M1079 INTERIOR LIGHT SWITCH/BOX AND CONDUIT REPLACEMENT (CONT)
(32) Install wire 706B terminal lug (46) on switch S32 (39).
(33) Tighten screw (47) on switch S32 (39).
(34) Install wire 706C terminal lug (48) on switch S32 (39).
(35) Tighten screw (49) on switch S32 (39).
(36) Install switch S32 (39) in outlet box (18) with two screws
(50).
(37) Install cover (51) on outlet box (18) with two screws (52).
c. Follow-On Maintenance.
(1) Connect AC power (TM 9-2320-365-10).
(2) Connect batteries (para 7-48).
(3) Check proper operation of fluorescent lights (TM 9-2320-
365-10).
(4) Check proper operation of blackout lights (TM 9-2320-
365-10).
(5) Close LH and RH doors (TM 9-2320-365-10).
End of Task.
16-312