TM 9-2320-365-20-4
16-53. M1079 110 VAC OUTLET/BOX AND CONDUIT REPLACEMENT (CONT)
NOTE
Perform steps (7) through (12) if conduit is
being installed on 110 vac outlet box J233 or
J232.
(7) Install conduit connector (14) in raceway (15) with lock
nut (16).
(8) Route supply wires (5), neutral wire (6), and ground wire
(7) through conduit connector (14).
(9) Install conduit nuts (17 and 18) and two ferrules (19) on
conduit (20).
(10) Route supply wires (5), neutral wire (6), and ground wire
(7) through conduit (20).
(11) Install conduit (20) on conduit connector (14) with
conduit nut (17).
(12) Install raceway cover (21) on raceway (22) with 12
washers (23), lockwashers (24), and screws (25).
16-346