TM 9-2320-365-20-4
16-61. M1079 5/20 AMP DC CIRCUIT BREAKER REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
AC power disconnected (TM 9-2320-365-10).
Batteries disconnected (para 7-48).
LH and RH doors opened (115 degrees) (TM 9-2320-
365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Materials/Parts
Dispenser, Pressure Sensitive Adhesive Tape
(Item 21, Appendix D)
a. Removal.
(1) Loosen screw (1) on cover (2).
(2) Open cover (2) on relay box (3).
NOTE
Perform steps (3) and (4) on circuit breaker
CB11.
Tag wires and connection points prior to
removal.
(3) Remove screw (4), washer (5), and wires 1507 and
1507A terminal lugs (6 and 7) from left terminal on circuit
breaker CB11 (8).
(4) Remove screw (9), washer (10), and wire 49 terminal lug
(11) from right terminal on circuit breaker CB11 (8).
Change 1
16-393