TM 9-2320-365-20-4
16-62. M1079 110 VAC AND 24 VDC RELAY REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
AC power disconnected (TM 9-2320-365-10).
Batteries disconnected (para 7-48).
LH and RH doors opened (115 degrees) (TM 9-2320-
365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
a. Removal.
(1) Loosen screw (1) on cover (2).
(2) Open cover (2) on relay box (3).
NOTE
All relays are replaced the same way. Relay
K35 shown.
(3) Remove relay K35 (4) from relay socket (5).
16-397