TM 9-2320-365-20-4
16-64. M1079 15/20/30 AND 50 AMP AC CIRCUIT BREAKER REPLACEMENT (CONT)
NOTE
Tag wires and connection points prior to
removal.
All eight circuit breakers are removed the same
way. Circuit breaker CB8 shown.
Refer to Table 16-8. M1079 Circuit Breakers
and Wire Numbers for details.
Remove plastic cable ties as required.
(2) Loosen screw (4) on circuit breaker CB8 (5).
(3) Remove wires 400 (6) and 415 (7) from circuit breaker
CB8 (5).
(4) Remove circuit breaker CB8 (5) from 110/208 VAC
POWER DISTRIBUTION PANEL (8).
Table 16-8. M1079 Circuit Breakers and Wire Numbers
Circuit Breaker
Amperage
Wire Number
CB2
30AMP
1500/1501/1502
CB3
50AMP
500AA/501BB/502CC
CB4
15AMP
NOT USED
CB5
20AMP
701A
CB6
15AMP
708BB
CB7
20AMP
701B
CB8
15AMP
400/415
CB9
20AMP
701C
16-420