16-68. M1079 110/208 VAC POWER IN/OUT CABLE REPLACEMENT (CONT)
(10) Remove dust cap (26) from 110/208 vac POWER IN
connector (27).
(11) Remove sealing compound from heads of three screws
(28), screw (29), and edges of 110/208 vac POWER IN
connector (27).
NOTE
Steps (12) through (14) require the aid of an
assistant.
(12) Remove four nuts (30), lockwashers (31), and washers
(32) from three screws (28) and screw (29). Discard
lockwashers.
(13) Remove three screws (28) from 110/208 vac POWER IN
connector (27).
(14) Remove screw (29), dust cap (26), 110/208 vac POWER
IN connector (27), and gasket (33) from 110/208 vac
power entry panel (5).
16-452