TM 9-2320-365-20-1
2-892
1.
START
YES
NO
Chemical detector indicator
operates.
If 12 vdc is not present,
wire 1803 is faulty.
KNOWN INFO
POSSIBLE PROBLEMS
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R #89
REASON FOR QUESTION
Is 12 vdc present at
terminal lug TL97?
Go to step 3 of this fault.
Faulty dashboard cable
assembly.
Faulty chemical alarm kit
cable assembly.
Faulty chemical alarm.
e80. CHEMICAL ALARM DOES NOT OPERATE
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P