TM 9-2320-365-20-1
2-933
CONTINUITY TEST
CONTINUITY TEST
(1) Remove kick panel (para 16-3).
(2) Disconnect connector P112 from manifold
valve assembly.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
connector P110-C.
(5) Connect negative (-) probe of multimeter to
connector P112-E and note reading on
multimeter.
(6) If continuity is not present, replace CTIS cable
assembly (para 7-53).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P110-F.
(3) Connect negative (-) probe of multimeter to
connector P112-A and note reading on
multimeter.
(4) If continuity is not present, replace CTIS
cable assembly (para 7-53).