TM 9-2320-365-20-1
2-1047
CONTINUITY TEST
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector J93-2.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3014
(para 2-40) or replace start and charging cable
assembly (para 7-82).
(5) If continuity is present, replace ether valve
(para 4-15).
(6) Raise spare tire (TM 9-2320-365-10).
(1) Remove instrument panel assembly for access
(para 7-15).
(2) Disconnect connector PX13 from ether start
switch.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
ether start switch terminal 1.
(5) Connect negative (-) probe of multimeter to
ether start switch terminal 3.
(6) Position ether start switch to on
(TM 9-2320-365-10) and note reading on
multimeter.
(7) If continuity is not present, replace ether
start switch (para 7-18).