TM 9-2320-365-20-1
2-1055
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect jumper wire to connector P42-1.
(3) Lower cab (TM 9-2320-365-10).
(4) Connect positive (+) probe of multimeter to
connector P31-15.
(5) Connect negative (-) probe of multimeter to
jumper wire and note reading on multimeter.
(6) If continuity is not present, repair wire 1403
(para 2-40) or replace engine control cable
assembly (para 7-72).
(7) Raise cab (TM 9-2320-365-10).
(8) Remove jumper wire from connector P42.
(9) Connect connector P42 to ether sensor
connector.
(10) Connect connector clamp on ether sensor
connector.
(11) Lower cab (TM 9-2320-365-10).