CONTINUITY TEST
(1) Disconnect batteries (para 7-48).
(2) Remove nut, lockwasher, and terminal lug
TL23 from auxiliary starter solenoid.
Discard lockwasher.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
terminal lug TL23.
(5) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6) If continuity is not present, repair wire 93
from terminal lug TL23 to terminal lug TL25
(para 2-40) or replace start and charging
cable assembly (para 7-82).
(7) Install terminal lug TL23 on auxiliary starter
solenoid with lockwasher and nut.
Change 1 2-165
TM 9-2320-365-20-1