Home
Download PDF
Order CD-ROM
Order in Print
CONTINUITY TEST - TM-9-2320-365-20-1_373
CONTINUITY TEST - TM-9-2320-365-20-1_375
/.5tonm1078v1-5/TM-9-2320-365-20-1 Palletized Load System Model M1074/M1075 NSN 2320-01-304-2277 2320-01-304-2278 Manual
Page Navigation
323
324
325
326
327
328
329
330
331
332
333
KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
If
continuity
is not present,
200 AMP terminal block is
faulty.
Is
continuity
present from
200 AMP terminal block
12V BAT left terminal stud
to right terminal stud?
Continuity Test
or
STE/ICE-R Test #91
NO
YES
14.
Circuit breaker
CB70 OK.
Battery(ies) OK.
Cab to chassis ground strap
OK.
PDP to cab ground cable OK.
Shunt OK.
Starter to shunt 24 VDC cable
OK.
Battery to shunt cable
assembly OK.
Starter to chassis ground
cable OK.
POSSIBLE PROBLEMS
Faulty 200 AMP reverse
polarity relay.
Faulty 200 AMP terminal
block.
Faulty 200 AMP terminal block
to PDP 12 VDC cable.
Faulty 200 AMP terminal block
to reverse polarity
relay
12
VDC load cable.
Faulty 200 AMP terminal block
to reverse polarity
relay
12
VDC battery cable.
Faulty battery to 200 AMP
terminal block 12 VDC cable
assembly.
Replace 200 AMP terminal
block (para 20-69).
TM 9-2320-365-20-1
2-256.24 Change 1
e3. 12 VDC AND 24 VDC CIRCUITS DO NOT OPERATE (CONT)
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business