Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
CAUTION
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(9) Install PDP cover (para 16-2).
(10) Connect batteries (para 7-48).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to connector PX17 socket 1.
(3) Connect negative (-) probe of multimeter
to relay K2 socket 86 on PDP and note
reading on multimeter.
(4) If continuity is not present, repair wire
1548 from connector PX17 socket 1
to relay K2 socket 86 on PDP (para
2-40) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(5) If continuity is present, repair wire 1586
from connector PX17 socket 5 to circuit
breaker CB70 socket 4 on PDP (para 2-40)
or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(6) Connect connector PX17 to master power
switch connector.
(7) Install instrument panel (para 7-15).
(8) Install relay K2 in PDP.
Change 1 2-274.13
TM 9-2320-365-20-1