CONTINUITY TEST
(1) Remove personnel heater assembly for
access (para 18-9).
(2) Disconnect connector P913 from
connector J913.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to connector P901 pin 4.
(5) Connect negative (-) probe of multimeter
to connector P913 pin 12 and note reading
on multimeter.
(6) If continuity is not present, repair wire 1550
from connector P901 pin 4 to connector
P913 pin 12 (para 2-40) or replace auxiliary
panel cable assembly (para 7-49).
(7) If continuity is present, repair wire 1550
from connector J913 socket 12 to
connector PX26 socket 1 (para 2-40) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(8) Connect connector P913 to connector
J913.
(9) Install personnel heater assembly (para
18-9).
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
Change 1 2-356.5
TM 9-2320-366-20-1