CAUTIONCONTINUITY TESTCONTINUITY TESTNOTEInspect connector pins/sockets for damage,corrosion, and serviceability. Check thatconnector pins are not pushed back andare capable of making good contact.Use care when testing electrical connectors.Do not damage connector pins or socketswith multimeter probes. Failure to complymay result in damage to equipment.(1) Disconnect connector PX7 from lightedindicator display.(2) Set multimeter to ohms.(3) Connect positive (+) probe of multimeter toterminal lug TL161.(4) Connect negative (-) probe of multimeter toconnector PX7 pin 16 and note reading onmultimeter.(5) If continuity is not present, repair wire 1532from terminal lug TL161 to connector PX7pin 16 (para 2-40) or replace WTEC IIdashboard cable assembly (para 7-10) orWTEC III dashboard cable assembly (para7-11).(6) If continuity is present, replace lightedindicator display (para 7-16).(7) Connect connector PX7 to lighted indicatordisplay.(8) Install instrument panel assembly (para7-15).(1) Disconnect connector PX7 from lightedindicator display.(2) Set multimeter to ohms.(3) Connect positive (+) probe of multimeter toterminal lug TL160.(4) Connect negative (-) probe of multimeter toconnector PX7 pin 19 and note reading onmultimeter.(5) If continuity is not present, repair wire 1536from terminal lug TL160 to connector PX7pin 19 (para 2-40) or replace WTEC IIdashboard cable assembly (para 7-10) orWTEC III dashboard cable assembly (para7-11).(6) If continuity is present, replace lightedindicator display (para 7-16).(7) Connect connector PX7 to lighted indicatordisplay.(8) Install instrument panel assembly (para7-15).Change 1 2-361TM 9-2320-365-20-1