TM 9-2320-365-20-1
2-417
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
connector P110-E.
(3) Connect negative (-) probe of multimeter to
connector PX7-9 and note reading on
multimeter.
(4) If continuity is not present, go to step 9 of
this fault.
(5) If continuity is present, replace CTIS ECU
(para 12-6).
(6) Connect lighted indicator display to connector
PX7.
(7) Position lighted indicator display in
instrument panel assembly with four screws.
(8) Tighten four screws to 6-10 lb-in. (1 N·m).
(9) Connect batteries (para 7-48).