CONTINUITY TEST
(1) Disconnect batteries (para 7-48).
(2) Remove relay K20 from PDP.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
circuit breaker CB67 socket 3 on PDP.
(5) Connect negative (-) probe of multimeter to
relay K20 terminal 87 on PDP and note
reading on multimeter.
(6) If 12 VDC is not present, repair wire 1914
from circuit breaker CB67 socket 3 to relay
K20 terminal 87 on PDP (para 2-40) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(7) Install circuit breaker CB67 in PDP.
(8) Connect batteries (para 7-48).
Change 1 2-584.55