CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
relay K20 terminal 85 on PDP.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3054
from relay K20 terminal 85 on PDP to terminal
board TB2 position 44 on PDP (para 2-40) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(5) If continuity is present, replace relay K20
(para 7-9).
(6) Install relay K20 in PDP.
(7) Install PDP cover (para 16-2).
Change 1 2-594.17
TM 9-2320-365-20-1