TM 9-2320-365-20-1
2-601
CONTINUITY TEST
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
LED socket.
(3) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4) If continuity is not present, repair wire 3091
(para 2-40) or replace front lights cable
assembly (para 7-74).
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
inside of housing.
(3) Connect negative (-) probe of multimeter to
socket and note reading on multimeter.
(4) If continuity is present, replace composite
front light assembly blackout marker LED
(para 7-33).
(5) If continuity is not present, replace composite
front light assembly (para 7-33).
(6) Open blackout marker lamp.
(7) Install blackout marker lamp in socket.
(8) Install preformed packing and cover on housing
with five screws.