(1) Drain air tanks (TM 9-2320-365-10).
(2) Loosen air hose 502 at AIR IN P port.
(3) Start engine and charge air tanks
(TM 9-2320-365-10).
(4) Check for presence of air at air hose 502.
(5) If air is not present, go to step 9 of this
fault.
(6) If air is present, replace air/hydraulic manifold
(para 19-4).
(7) Drain air tanks (TM 9-2320-365-10).
(8) Tighten air hose 502 at AIR IN P port.
Change 1 2-1968.5