PRESSURE TEST
(1) Position drain pan under air/hydraulic
manifold
(2) Disconnect hydraulic hose 513 from
PILOT port.
(3) Connect STE/ICE-R between hydraulic
hose 513 and PILOT port.
(4) Start engine (TM 9-2320-365-10).
(5) Position SUSPENSION knob to LOWER
(TM 9-2320-365-10).
(6) Position FUNCTION SELECT knob
to SUSPENSION (TM 9-2320-365-10).
(7) Push and hold PUMP plunger button
(TM 9-2320-365-10) and perform
STE/ICE-R Test #51.
(8) If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, go to step 6 of this fault.
(9) If 2,500-4,000 psi (17,238-27,580 kPa) is
present, repair or replace air/hydraulic
manifold (para 19-4).
(10) Disconnect STE/ICE-R from hydraulic hose
513 and PILOT port.
(11) Connect hydraulic hose 513 to PILOT port.