PRESSURE TESTChange 1 2-1970.13TM 9-2320-365-20-2(1) Disconnect hydraulic hose 511 fromsuspension release tee fitting LHinput port.(2) Connect STE/ICE-R between hydraulichose 511 and suspension releasetee fitting LH input port.(3) Start engine (TM 9-2320-365-10).(4) Position SUSPENSION knob to LOWER(TM 9-2320-365-10).(5) Position FUNCTION SELECT knob toSUSPENSION (TM 9-2320-365-10).(6) Push and hold PUMP plunger button(TM 9-2320-365-10) and performSTE/ICE-R Test #51.(7) If 2,500-4,000 psi (17,238-27,580 kPa) isnot present, go to step 5 of this fault.(8) If 2,500-4,000 psi (17,238-27,580 kPa) ispresent, replace hydraulic hose 511(para 19-11).(9) Disconnect STE/ICE-R from hydraulic hose511 and suspension release tee fittingLH input port.(10) Connect hydraulic hose 511 to suspensionrelease tee fitting LH input port.(11) Repeat steps (2) through (12) on hydraulichose 509 and suspension release teefitting RH input port.