YES
TM 9-2320-365-20-2
2-1192 Change 1
2.
KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE-R Test #91
REASON FOR QUESTION
Repair or replace wire 701AA
(para 2-40).
POSSIBLE PROBLEMS
110 VAC outlets J232 and
J233 OK in normal mode.
FORWARD RECEPTACLE
OVERRIDE switch S34 OK.
Faulty wire 701AA.
Faulty wire 702AA.
Is continuity present on wire
701AA from K35 relay base
terminal 7 to FORWARD
RECEPTACLE OVERRIDE
switch S34?
If continuity is not present,
wire 701AA is faulty. If
continuity is present, wire
702AA is faulty.
Repair or replace wire 702AA
(para 2-40).
NO
e109. M1079 110 VAC OUTLETS J232 AND J233 DO NOT OPERATE IN BLACKOUT OVERRIDE
MODE (CONT)