TM 9-2320-365-20-2
2-1265
(10) Connect negative (-) probe of multimeter to
bottom input terminal on circuit breaker CB2 and
note reading on multimeter.
(11) If continuity is not present in steps (6), (8), and
(10), replace circuit breaker CB2 (para 16-64).
(12) Install circuit breaker CB2 on 110/208 VAC
POWER DISTRIBUTION PANEL.
(1) Remove six screws and cover from 110/208
VAC POWER DISTRIBUTION PANEL.
(2) Remove circuit breaker CB2 from 110/208 VAC
POWER DISTRIBUTION PANEL.
(3) Position circuit breaker CB2 to ON
(TM 9-2320-365-10).
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter to top
output terminal on circuit breaker CB2.
(6) Connect negative (-) probe of multimeter to top
input terminal on circuit breaker CB2 and note
reading on multimeter.
(7) Connect positive (+) probe of multimeter to
middle output terminal on circuit breaker CB2.
(8) Connect negative (-) probe of multimeter to
middle input terminal on circuit breaker CB2 and
note reading on multimeter.
(9) Connect positive (+) probe of multimeter to
bottom output terminal on circuit breaker CB2.
CONTINUITY TEST