TM 9-2320-365-20-2
2-1283
(1) Remove heater deflector/duct and hood
(para 20-50).
(2) Disconnect connector J244A from heater
POWER RECEPTACLE connector.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
connector P244 pin A.
(5) Connect negative (-) probe of multimeter to
connector J244A socket A and note reading on
multimeter.
(6) Connect positive (+) probe of multimeter to
connector P244 pin C.
(7) Connect negative (-) probe of multimeter to
connector J244A socket C and note reading on
multimeter.
(8) Connect positive (+) probe of multimeter to
connector P244 pin D.
(9) Connect negative (-) probe of multimeter to
connector J244A socket D and note reading
on multimeter.
(10) If continuity is not present in step 5, 7, or 9,
replace M1079 heater power cable (para
20-50).
(11) Connect connector J244A to heater POWER
RECEPTACLE connector.
CONTINUITY TEST