TM 9-2320-365-20-22-1319CONTINUITY TEST(1) Remove six screws and cover from 110/208VAC POWER DISTRIBUTION PANEL.(2) Loosen screw in terminal board TB3.(3) Remove wire 3085L from terminal board TB3.(4) Set multimeter to ohms.(5) Connect positive (+) probe of multimeter toJ237 24 vdc ground (G) binding post.(6) Connect negative (-) probe of multimeter toterminal board TB3 wire 3085L and notereading on multimeter.(7) If continuity is not present, repair or replacewire 3085L (para 2-40).(8) Position wire 3085L in terminal board TB3.(9) Tighten screw in terminal board TB3.(10) Install cover on 110/208 VAC POWERDISTRIBUTION PANEL with six screws.