TM 9-2320-365-20-2
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
RESISTANCE TEST
Change 1 2-1377
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter
to connector P119 pin p.
(3) Connect negative (-) probe of multimeter to
connector P119 pin r and note reading on
multimeter.
NOTE
A good turbine speed sensor
will return a reading of 200-400
ohms resistance as follows:
a. 200 ohms at -40°F (-40°C).
b. 300 ohms at 68°F (20°C).
c. 400 ohms at 230°F (110°C).
(4) Connect negative (-) probe of multimeter to
all other pins in connector P119 and note
reading on multimeter.
(5) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(6) If 200-400 ohms resistance is not present
in step 4, or continuity is present in step 5
or step 6, notify DS Maintenance.
(7) If 200-400 ohms resistance is present in
step 3, and continuity is not present in
step 5 or step 6, replace WTEC II TEPSS
(para 8-2).
(8) Connect connector J115 to WTEC II
TEPSS.
(9) Install instrument panel assembly (para
7-15).
(10) Connect connector P119 to connector
J119.
(11) Position front grille on cab with washer
and screw.
(12) Position two washers and screws in front
grille.
(13) Tighten screw to 48-60 lb-in. (5-7 N·m).
(14) Tighten two screws to 24 lb-in. (3 N·m).
(15) Clear diagnostic codes (para 8-4).