TM 9-2320-365-20-2
2-1093
CONTINUITY TEST
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
output terminal of circuit breaker CB8.
(3) Connect negative (-) probe of multimeter to
wire 415 terminal lug in fan switch S35 outlet
box and note reading on multimeter.
(4) If continuity is not present, repair or replace
415 (para 2-40).
CONTINUITY TEST
(1) Loosen terminal 4 screw on fan terminal board.
(2) Remove wire 415A from fan terminal board.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
wire 415A terminal lug.
(5) Connect negative (-) probe of multimeter to
other end of wire 415A and note reading on
multimeter.
(6) If continuity is not present, repair or replace
wire 415A (para 2-40).
(7) Position wire 415A in fan terminal board.
(8) Tighten terminal 4 screw on fan terminal board.