CAUTION
CONTINUITY TEST
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
Change 1 2-1523
Loose or dirty connectors may cause
intermittent loss of power to transmission
ECU and diagnostic codes to be logged.
Ensure that all connectors are clean and tight
before performing troubleshooting. Failure to
comply may result in incorrect test results.
Table 2-33. WTEC III Cab Transmission Harness
Transmission Solenoid Test Points
Sub
Code
Jumper
Across
Connector P114
Negative (-)
Probe
12
13
14
15
16
21
22
23
24
26
J119M to J119B
J119T to J119N
J119C to J119V
J119W to J119B
J119U to J119N
J119F to J119H
J119D to J119V
J119P to J119S
J119J to J119B
J119K to J119A
(1) Remove two screws and washers from
front grille.
(2) Remove screw and washer from front
grille.
(3) Remove front grille from cab.
(4) Disconnect connector P119 from
connector J119.
(5) Remove kick panel (para 16-3).
(6) Disconnect connector clamp from
connector P114.
(7) Disconnect connector P114 from WTEC III
transmission ECU.
(8) Install jumper wire on connector J119 for
appropriate sub code. Refer to Table 2-33.
WTEC III Cab Transmission Harness
Transmission Solenoid Test Points.
(9) Set multimeter to ohms.
(10) Connect positive (+) probe of multimeter
to connector P114. Refer to Table 2-33.
WTEC III Cab Transmission Harness
Transmission Solenoid Test Points.
P114-1
P114-2
P114-5
P114-1
P114-2
P114-3
P114-7
P114-19
P114-1
P114-19
P114-4
P114-20
P114-17
P114-21
P114-6
P114-22
P114-17
P114-23
P114-8
P114-24
Positive (+)
Probe
TM 9-2320-365-20-2
(11) Connect negative (-) probe of multimeter to
connector P114 and note reading on
multimeter. Refer to Table 2-33. WTEC III
Cab Transmission Harness Transmission
Solenoid Test Points.
(12) Connect negative (-) probe of multimeter to
all other sockets in connector P114, one at
a time, and note reading on multimeter.
(13) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(14) If continuity is not present, in step 11, or
continuity is present in step 12 or 13,
replace WTEC III cab transmission harness
(para 7-87).
(15) Remove jumper wire from connector J119.
(16) Connect connector P119 to connector