TM 9-2320-365-20-2
2-1748
1.
YES
NO
YES
NO
2.
Engine runs.
Visual inspection
START
Visual inspection
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
j6. NOISY AIR COMPRESSOR OPERATION
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10).
Kinked compressor oil hoses.
Kinked compressor coolant
hoses.
Loose or missing air
compressor mounting
hardware.
Faulty air compressor.
Kinked compressor coolant
hoses will cause overheating
and noisy compressor
operation.
Are air compressor
coolant hoses free from
kinks?
Kinked compressor coolant
hoses.
Loose or missing air
compressor mounting
hardware.
Faulty air compressor.
Kinked compressor
oil hoses will cause
noisy air compressor
operation.
Are air compressor
oil hoses free from kinks?
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Replace air compressor
oil hose(s).
Replace air compressor
coolant hose(s) (para 6-11).
Air compressor oil
hoses OK.