TM 9-2320-365-20-4
16-35. M1079 RH DOOR ASSEMBLY REPLACEMENT/REPAIR (CONT)
(40) Install two latch arms (45) on RH door (5) with two bolts
(46), sleeve (47), two spacers (48), spring washers (49),
washers (50), and self-locking nuts (51).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(41) Apply sealing compound around heads of two bolts (46).
(42) Install three washers (52) and latch rod (53) on two latch
arms (45) and latch arm (42) with three pins (54),
washers (55), and cotter pins (56).
(43) Install handle (57) on RH door (5) with two washers (58)
and screws (59).
16-206