TM 9-2320-365-20-4
16-55. M1079 DOOR AJAR SWITCH AND CONDUIT REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Adjustment
d. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Batteries disconnected (para 7-48).
LH door closed (TM 9-2320-365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Key, Socket Head Screw (Item 35, Appendix B)
Materials/Parts
Dispenser, Pressure Sensitive Adhesive Tape (Item
21, Appendix D)
Lockwasher (11) (Item 81, Appendix G)
Personnel Required
(2)
a. Removal.
(1) Loosen screw (1) on switch lever (2).
(2) Remove switch lever (2) from switch S17 (3).
(3) Remove three screws (4), lockwashers (5), cover (6),
and gasket (7) from switch S17 (3).
Discard
lockwashers.
NOTE
Tag wires and connection points prior to
disconnecting.
(4) Loosen screw 3 (8) in switch S17 (3).
(5) Remove wire 709 (9) from switch S17 (3).
(6) Loosen screw 4 (10) in switch S17 (3).
(7) Remove wire 1509E (11) from switch S17 (3).
16-357