TM 9-2320-365-20-5
20-45. M1079 HEATER THERMOSTAT CABLE REPLACEMENT
This task covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-365-10).
AC power disconnected (TM 9-2320-365-10).
LH and RH doors opened (115 degrees) (TM 9-2320-
365-10).
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
Materials/Parts
Dispenser, Pressure Sensitive Adhesive Tape
(Item 21, Appendix D)
a. Removal.
NOTE
Tag connectors and connection points prior
to disconnecting.
(1) Disconnect connector J245 (1) from thermostat
connector (2).
(2) Disconnect connector P245A (3) from heater control unit
(4).
b. Installation
(1) Connect connector P245A (3) to heater control unit (4).
(2) Connect connector J245 (1) to thermostat connector (2).
c. Follow-On Maintenance.
(1) Connect AC power (TM 9-2320-365-10).
(2) Check thermostat for proper operation (TM 9-2320-365-
10).
(3) Close LH and RH doors (TM 9-2320-365-10).
End of Task.
20-236